Review



mouse anti human clec10a cd301 conjugated  (R&D Systems)


Bioz Verified Symbol R&D Systems is a verified supplier
Bioz Manufacturer Symbol R&D Systems manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 92

    Structured Review

    R&D Systems mouse anti human clec10a cd301 conjugated
    Mouse Anti Human Clec10a Cd301 Conjugated, supplied by R&D Systems, used in various techniques. Bioz Stars score: 92/100, based on 7 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/mouse anti human clec10a cd301 conjugated/product/R&D Systems
    Average 92 stars, based on 7 article reviews
    mouse anti human clec10a cd301 conjugated - by Bioz Stars, 2026-04
    92/100 stars

    Images



    Similar Products

    92
    R&D Systems mouse anti human clec10a cd301 conjugated
    Mouse Anti Human Clec10a Cd301 Conjugated, supplied by R&D Systems, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/mouse anti human clec10a cd301 conjugated/product/R&D Systems
    Average 92 stars, based on 1 article reviews
    mouse anti human clec10a cd301 conjugated - by Bioz Stars, 2026-04
    92/100 stars
      Buy from Supplier

    93
    R&D Systems biotinylated anti human mgl antibody
    Biotinylated Anti Human Mgl Antibody, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/biotinylated anti human mgl antibody/product/R&D Systems
    Average 93 stars, based on 1 article reviews
    biotinylated anti human mgl antibody - by Bioz Stars, 2026-04
    93/100 stars
      Buy from Supplier

    93
    Elabscience Biotechnology recombinant human mgl clec10a protein
    Recombinant Human Mgl Clec10a Protein, supplied by Elabscience Biotechnology, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/recombinant human mgl clec10a protein/product/Elabscience Biotechnology
    Average 93 stars, based on 1 article reviews
    recombinant human mgl clec10a protein - by Bioz Stars, 2026-04
    93/100 stars
      Buy from Supplier

    93
    R&D Systems paper cd301 6xhistidine r d systems 4888 cl 050 l pha
    Paper Cd301 6xhistidine R D Systems 4888 Cl 050 L Pha, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/paper cd301 6xhistidine r d systems 4888 cl 050 l pha/product/R&D Systems
    Average 93 stars, based on 1 article reviews
    paper cd301 6xhistidine r d systems 4888 cl 050 l pha - by Bioz Stars, 2026-04
    93/100 stars
      Buy from Supplier

    90
    OriGene mouse anti-human clec10a monoclonal antibody oti2b10
    Three lectins, Galectin-4 C, Galectin-8 C, and <t>CLEC10A-Fc,</t> were extracted as candidate human endogenous lectins that recognize pancreatic cancer cells. ( a ) Among the 43 lectins, pancreatic cancer-reactive lectins were screened using flow cytometry. The difference (ΔMFI) between the median fluorescence intensity (MFI) of each lectin and the MFI of the control is shown in the heat map. Red arrows indicate lectins that met the criteria of MFI greater than 10 4 for the pancreatic cancer cell lines, Capan-1 or AsPC-1, and less than 10 4 for the pancreatic ductal cell line, hTERT-HPNE. ( b ) Histograms of Galectin-4 C, Galectin-8 C, and CLEC10A-Fc. The gray-filled histogram indicates control cells stained with PE-labeled BSA (for galectins) or PE-labeled anti-Fc antibody (for C-type lectins) used as negative controls, and the cyan line is the histogram of cells incubated with PE-labeled galectins or C-type lectins followed by PE-labeled anti-Fc antibody.
    Mouse Anti Human Clec10a Monoclonal Antibody Oti2b10, supplied by OriGene, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/mouse anti-human clec10a monoclonal antibody oti2b10/product/OriGene
    Average 90 stars, based on 1 article reviews
    mouse anti-human clec10a monoclonal antibody oti2b10 - by Bioz Stars, 2026-04
    90/100 stars
      Buy from Supplier

    92
    R&D Systems clec10a cd301 antibody
    Three lectins, Galectin-4 C, Galectin-8 C, and <t>CLEC10A-Fc,</t> were extracted as candidate human endogenous lectins that recognize pancreatic cancer cells. ( a ) Among the 43 lectins, pancreatic cancer-reactive lectins were screened using flow cytometry. The difference (ΔMFI) between the median fluorescence intensity (MFI) of each lectin and the MFI of the control is shown in the heat map. Red arrows indicate lectins that met the criteria of MFI greater than 10 4 for the pancreatic cancer cell lines, Capan-1 or AsPC-1, and less than 10 4 for the pancreatic ductal cell line, hTERT-HPNE. ( b ) Histograms of Galectin-4 C, Galectin-8 C, and CLEC10A-Fc. The gray-filled histogram indicates control cells stained with PE-labeled BSA (for galectins) or PE-labeled anti-Fc antibody (for C-type lectins) used as negative controls, and the cyan line is the histogram of cells incubated with PE-labeled galectins or C-type lectins followed by PE-labeled anti-Fc antibody.
    Clec10a Cd301 Antibody, supplied by R&D Systems, used in various techniques. Bioz Stars score: 92/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/clec10a cd301 antibody/product/R&D Systems
    Average 92 stars, based on 1 article reviews
    clec10a cd301 antibody - by Bioz Stars, 2026-04
    92/100 stars
      Buy from Supplier

    94
    R&D Systems mgl
    Three lectins, Galectin-4 C, Galectin-8 C, and <t>CLEC10A-Fc,</t> were extracted as candidate human endogenous lectins that recognize pancreatic cancer cells. ( a ) Among the 43 lectins, pancreatic cancer-reactive lectins were screened using flow cytometry. The difference (ΔMFI) between the median fluorescence intensity (MFI) of each lectin and the MFI of the control is shown in the heat map. Red arrows indicate lectins that met the criteria of MFI greater than 10 4 for the pancreatic cancer cell lines, Capan-1 or AsPC-1, and less than 10 4 for the pancreatic ductal cell line, hTERT-HPNE. ( b ) Histograms of Galectin-4 C, Galectin-8 C, and CLEC10A-Fc. The gray-filled histogram indicates control cells stained with PE-labeled BSA (for galectins) or PE-labeled anti-Fc antibody (for C-type lectins) used as negative controls, and the cyan line is the histogram of cells incubated with PE-labeled galectins or C-type lectins followed by PE-labeled anti-Fc antibody.
    Mgl, supplied by R&D Systems, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/mgl/product/R&D Systems
    Average 94 stars, based on 1 article reviews
    mgl - by Bioz Stars, 2026-04
    94/100 stars
      Buy from Supplier

    Image Search Results


    Three lectins, Galectin-4 C, Galectin-8 C, and CLEC10A-Fc, were extracted as candidate human endogenous lectins that recognize pancreatic cancer cells. ( a ) Among the 43 lectins, pancreatic cancer-reactive lectins were screened using flow cytometry. The difference (ΔMFI) between the median fluorescence intensity (MFI) of each lectin and the MFI of the control is shown in the heat map. Red arrows indicate lectins that met the criteria of MFI greater than 10 4 for the pancreatic cancer cell lines, Capan-1 or AsPC-1, and less than 10 4 for the pancreatic ductal cell line, hTERT-HPNE. ( b ) Histograms of Galectin-4 C, Galectin-8 C, and CLEC10A-Fc. The gray-filled histogram indicates control cells stained with PE-labeled BSA (for galectins) or PE-labeled anti-Fc antibody (for C-type lectins) used as negative controls, and the cyan line is the histogram of cells incubated with PE-labeled galectins or C-type lectins followed by PE-labeled anti-Fc antibody.

    Journal: Scientific Reports

    Article Title: Identification of CLEC10A as a human lectin for pancreatic ductal adenocarcinoma

    doi: 10.1038/s41598-025-02404-1

    Figure Lengend Snippet: Three lectins, Galectin-4 C, Galectin-8 C, and CLEC10A-Fc, were extracted as candidate human endogenous lectins that recognize pancreatic cancer cells. ( a ) Among the 43 lectins, pancreatic cancer-reactive lectins were screened using flow cytometry. The difference (ΔMFI) between the median fluorescence intensity (MFI) of each lectin and the MFI of the control is shown in the heat map. Red arrows indicate lectins that met the criteria of MFI greater than 10 4 for the pancreatic cancer cell lines, Capan-1 or AsPC-1, and less than 10 4 for the pancreatic ductal cell line, hTERT-HPNE. ( b ) Histograms of Galectin-4 C, Galectin-8 C, and CLEC10A-Fc. The gray-filled histogram indicates control cells stained with PE-labeled BSA (for galectins) or PE-labeled anti-Fc antibody (for C-type lectins) used as negative controls, and the cyan line is the histogram of cells incubated with PE-labeled galectins or C-type lectins followed by PE-labeled anti-Fc antibody.

    Article Snippet: Samples were pre-incubated with mouse anti-human CLEC10A monoclonal antibody (1:500, clone OTI2B10, OriGene; Cat# TA810180) and Alexa Fluor 488-conjugated rabbit anti-CD163 monoclonal antibody (1:500, clone EPR19518 , Abcam, Cambridge, UK; Cat# AB313665 ) at room temperature for 30 min.

    Techniques: Flow Cytometry, Fluorescence, Control, Staining, Labeling, Incubation

    CLEC10A is a human endogenous lectin with high affinity for pancreatic cancer cells. ( a ) Representative images of pancreatic cancerous and noncancerous tissues stained with three lectins (Galectin-4 C, Galectin-8 C, and CLEC10A-Fc). Scale bars, 10 μm. The arrowhead (▼) indicates the positive staining of the cell membrane. ( b ) Percentage of cases positive for lectin staining in pancreatic cancer cells (C) and pancreatic duct cells (N) in noncancerous tissue compared using Fisher’s exact test (NS: not significant, * P < 0.05).

    Journal: Scientific Reports

    Article Title: Identification of CLEC10A as a human lectin for pancreatic ductal adenocarcinoma

    doi: 10.1038/s41598-025-02404-1

    Figure Lengend Snippet: CLEC10A is a human endogenous lectin with high affinity for pancreatic cancer cells. ( a ) Representative images of pancreatic cancerous and noncancerous tissues stained with three lectins (Galectin-4 C, Galectin-8 C, and CLEC10A-Fc). Scale bars, 10 μm. The arrowhead (▼) indicates the positive staining of the cell membrane. ( b ) Percentage of cases positive for lectin staining in pancreatic cancer cells (C) and pancreatic duct cells (N) in noncancerous tissue compared using Fisher’s exact test (NS: not significant, * P < 0.05).

    Article Snippet: Samples were pre-incubated with mouse anti-human CLEC10A monoclonal antibody (1:500, clone OTI2B10, OriGene; Cat# TA810180) and Alexa Fluor 488-conjugated rabbit anti-CD163 monoclonal antibody (1:500, clone EPR19518 , Abcam, Cambridge, UK; Cat# AB313665 ) at room temperature for 30 min.

    Techniques: Staining, Membrane

    CLEC10A ligand is expressed in 60% of clinical pancreatic cancer cells. ( a ) Representative images of histochemically processed sections of clinical pancreatic cancer tissue analyzed for CLEC10A-Fc staining. Scale bars (Large window) 200 μm, (Small window) 10 μm. Staining intensity was scored according to the percentage of positive cells regardless of staining intensity as follows: 0, 0%; 1+, < 1%; 2+, 1–24; 3+, 25–49%; 4+, 50–74%; 5+, 75–100%. ( b ) A pie chart showing the percentage of each staining score in 113 processed sections of clinical pancreatic cancer tissue stained with CLEC10A-Fc.

    Journal: Scientific Reports

    Article Title: Identification of CLEC10A as a human lectin for pancreatic ductal adenocarcinoma

    doi: 10.1038/s41598-025-02404-1

    Figure Lengend Snippet: CLEC10A ligand is expressed in 60% of clinical pancreatic cancer cells. ( a ) Representative images of histochemically processed sections of clinical pancreatic cancer tissue analyzed for CLEC10A-Fc staining. Scale bars (Large window) 200 μm, (Small window) 10 μm. Staining intensity was scored according to the percentage of positive cells regardless of staining intensity as follows: 0, 0%; 1+, < 1%; 2+, 1–24; 3+, 25–49%; 4+, 50–74%; 5+, 75–100%. ( b ) A pie chart showing the percentage of each staining score in 113 processed sections of clinical pancreatic cancer tissue stained with CLEC10A-Fc.

    Article Snippet: Samples were pre-incubated with mouse anti-human CLEC10A monoclonal antibody (1:500, clone OTI2B10, OriGene; Cat# TA810180) and Alexa Fluor 488-conjugated rabbit anti-CD163 monoclonal antibody (1:500, clone EPR19518 , Abcam, Cambridge, UK; Cat# AB313665 ) at room temperature for 30 min.

    Techniques: Staining

    CLEC10A-expressing monocytic cells in pancreatic cancer stroma. ( a ) Left: Hematoxylin and eosin staining of representative pancreatic cancer tissue. Scale bars, 50 μm. Right: Immunostaining with anti-CLEC10A antibody in representative pancreatic cancer tissue. Scale bars, 50 μm. Cancer duct structures are surrounded by dotted lines (---); CLEC10A-expressing cells are indicated by arrowheads (▼). ( b ) Immunofluorescence staining of CLEC10A (red), CD163 (green), and nuclei (blue) in pancreatic cancer tissue; merge: yellow. Scale bars, 50 μm.

    Journal: Scientific Reports

    Article Title: Identification of CLEC10A as a human lectin for pancreatic ductal adenocarcinoma

    doi: 10.1038/s41598-025-02404-1

    Figure Lengend Snippet: CLEC10A-expressing monocytic cells in pancreatic cancer stroma. ( a ) Left: Hematoxylin and eosin staining of representative pancreatic cancer tissue. Scale bars, 50 μm. Right: Immunostaining with anti-CLEC10A antibody in representative pancreatic cancer tissue. Scale bars, 50 μm. Cancer duct structures are surrounded by dotted lines (---); CLEC10A-expressing cells are indicated by arrowheads (▼). ( b ) Immunofluorescence staining of CLEC10A (red), CD163 (green), and nuclei (blue) in pancreatic cancer tissue; merge: yellow. Scale bars, 50 μm.

    Article Snippet: Samples were pre-incubated with mouse anti-human CLEC10A monoclonal antibody (1:500, clone OTI2B10, OriGene; Cat# TA810180) and Alexa Fluor 488-conjugated rabbit anti-CD163 monoclonal antibody (1:500, clone EPR19518 , Abcam, Cambridge, UK; Cat# AB313665 ) at room temperature for 30 min.

    Techniques: Expressing, Staining, Immunostaining, Immunofluorescence

    Appearance of CLEC10A-expressing monocytic cells and coexistence of CLEC10A ligand on pancreatic cancer cells are poor prognostic factors in stage II and III cases. ( a ) Representative images of formalin-fixed paraffin-embedded (FFPE) sections of clinical pancreatic cancer tissues stained with anti-CLEC10A antibody. Scale bars, 100 μm. Staining intensity was scored according to the number of positive cells in the 20× field of view as follows: 0 (0 fields); 1+ (1–2 fields); 2+ (> 3 fields). ( b ) Classification based on the combination of CLEC10A and CLEC10A ligand expression intensity. ( c ) Kaplan–Meier curve comparing category Low ( n = 23) with category High ( n = 5). Log-rank test (* P < 0.05) was used.

    Journal: Scientific Reports

    Article Title: Identification of CLEC10A as a human lectin for pancreatic ductal adenocarcinoma

    doi: 10.1038/s41598-025-02404-1

    Figure Lengend Snippet: Appearance of CLEC10A-expressing monocytic cells and coexistence of CLEC10A ligand on pancreatic cancer cells are poor prognostic factors in stage II and III cases. ( a ) Representative images of formalin-fixed paraffin-embedded (FFPE) sections of clinical pancreatic cancer tissues stained with anti-CLEC10A antibody. Scale bars, 100 μm. Staining intensity was scored according to the number of positive cells in the 20× field of view as follows: 0 (0 fields); 1+ (1–2 fields); 2+ (> 3 fields). ( b ) Classification based on the combination of CLEC10A and CLEC10A ligand expression intensity. ( c ) Kaplan–Meier curve comparing category Low ( n = 23) with category High ( n = 5). Log-rank test (* P < 0.05) was used.

    Article Snippet: Samples were pre-incubated with mouse anti-human CLEC10A monoclonal antibody (1:500, clone OTI2B10, OriGene; Cat# TA810180) and Alexa Fluor 488-conjugated rabbit anti-CD163 monoclonal antibody (1:500, clone EPR19518 , Abcam, Cambridge, UK; Cat# AB313665 ) at room temperature for 30 min.

    Techniques: Expressing, Formalin-fixed Paraffin-Embedded, Staining